CFYCL - TETRAFLUOROMETHANE IN THERMOMETER,31 GP-Y 00 U-A 20 Y

  • MSDS: CFYCL
  • Manufacturer: UNION CARBIDE CORP LINDE DIV
  • Product Name: TETRAFLUOROMETHANE IN THERMOMETER,31 GP-Y 00 U-A 20 Y
  • National Stock Number: 6685-00-076-1954
Product Identification

Product ID:TETRAFLUOROMETHANE IN THERMOMETER,31 GP-Y 00 U-A 20 Y
MSDS Date:11/01/1988
FSC:6685
NIIN:00-076-1954
MSDS Number: CFYCL

Responsible Party
UNION CARBIDE CORP LINDE DIV
39 OLD RIDGEBURY RD
DANBURY, CT 06817-0001
US

Emergency Phone: 203-744-3487/800-822-4357

Info Phone: 203-744-3487

Cage: 36346

Contractor
YORK INTERNATIONAL CORP
YORK, PA 17403 US

Telephone: 717-771-7890

Cage: 66935

Ingredients

TETRAFLUOROMETHANE

CAS: 75-73-0

RTECS: FG4920000

Fraction By Weight: 100%

Hazards

LD50 LC50 Mixture:NOT RELEVANT
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NONE. IF BROKEN/IN FIRE: DIZZINESS, HEADACHE,
FATIGUE, NAUSEA, VOMITING, CONFUSION, FROSTBITE
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:GET MEDICAL ATTENTION IF SYMPTOMS PERSIST. EYES:IMMEDIATELY
FLUSH WITH WATER FOR 15 MINUTES. CALL PHYSICIAN. INHALED:MOVE TO
FRESH AIR. PROVIDE OXYGEN/CPR IF NEEDED. SKIN:TREAT FOR POSSIBLE
FROSTBITE USING WARM WATER (105F), THEN FLUSH SKINWITH PLENTY OF
WATER. ORAL:UNLIKELY TO OCCUR. NOTE TO PHYSICIAN:CATECHOLAMINE
DRUGS (ADRENALINE) SHOULD NOT BE USED DUE TO SENSITIZING EFFECT OF
FLUOROCARBONS.

Fire Fighting

Flash Point:NONE
Lower Limits:NOT RELEVANT
Upper Limits:NOT RELEVANT
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING AND NIOSH-APPROVED
SELF-CONTAINED BREATHING APPARATUS. HAZARDOUS DECOMPOSITION
PRODUCTS MAY BE FORMED.
Unusual Fire/Explosion Hazard:CONTAINER MAY RUPTURE DUE TO HEAT OF
FIRE.

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE LEAKING THERMOMETER TO
EXHAUST HOOD OR OUTDOOR AREA.
Neutralizing Agent:NOT RELEVANT

Handling

Handling and Storage Precautions:STORE AWAY FROM INCOMPATIBLES. KEEP
OUT OF REACH OF SMALL CHILDREN.
Other Precautions:WASH HANDS AFTER HANDLING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:ADEQUATE
Protective Gloves:NONE SHOULD BE NEEDED.
Eye Protection:SAFETY GLASSES RECOMMENDED
Other Protective Equipment:NONE SHOULD BE NEEDED.
Work Hygienic Practices:OBSERVE GOOD INDUSTRIAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES.
Supplemental Safety and Health
THIS IS A THERMOMETER WHICH HAS SMALL AMOUNTS OF TETRAFLUOROMETHANE GAS
(3-4 OZ). FORMULA CHANGED. FOR PREVIOUS FORMULATION, SEE PNI A,
SAME NSN.

Chemical Properties

HCC:G3
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:B.P. Text:-198F,-128C
Melt/Freeze Pt:M.P/F.P Text:-299F,-184C
Vapor Pres:GAS
Vapor Density:3.038
Spec Gravity:GAS
Viscosity:NOT RELEVANT
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS AT NORMAL TEMPERATURE AND
PRESSURE
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALUMINUM, CARBON DIOXIDE ABOVE 1000C, ALLOYS OF MORE THAN 2% MAGNESIUM
IN PRESENCE OF WATER
Stability Condition to Avoid:EXCESSIVE HEAT
Hazardous Decomposition Products:MAY FORM FLUORINE/CARBONYL FLUORIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.